We run eight 3.5t vans on urban delivery routes, roughly 90 to 120 miles a day, back at the yard by 7pm. Lease on two diesels ends next spring so we're costing out electric. Site has a 100A supply and the landlord isn't keen on an upgrade. My instinct is six 7 kW overnight points and accept the slower turnaround, but our ops manager wants one 50 kW DC unit so vans can rotate through in the middle of the day. Anyone been through this? Curious what demand charges actually looked like, and whether overnight AC kept up in winter.